![]() After activity is found in a station, the operator must determine the EXTENT of the termite activity level. registered chemical bait matrix, will only be applied when 2 or more stations are found active with termites at a given location. Important Note: The HomeGuard™ Truth Termite Bait or an E.P.A. At this time operator may choose to hasten temperature loss by adding 2-3 ounces of distilled water in bait matrix as previously described in “Installation Procedure” section in manual. Take refill cartridge and place back inside station. If no activity is occurring, then remove the bait matrix by grabbing top and pulling upward. Recheck to confirm there is no termite activity. HomeGuard™ Truth Termite Bait replacement cartridges are pre-manufactured and are installed as follows:įirst, remove the top lid of bait station. If matrix needs to be replaced due to damage or erosion, “replaced bait matrix.” If there is NO activity viewed in the station: If these signs occur it is mandatory to remove the top lid of the station and check for activity by closer inspection. Bait matrix inside of station appears to tilt or lean to one side.Live termites are viewed inside the station.Station’s top cap shows signs of dirt or mud build up inside the station.Station’s interior matrix has sunken inside the cylinder.Look through the transparent top to determine if termite activity has occurred. #HOW TO UNINSTALL HOMEGUARD ACTIVITY MONITOR PROFESSIONAL#The HomeGuard™ Monitoring System was designed to allow a trained professional to check the station without effecting or disturbing termite activity within the station.Ģ. Continuing labeling each station in sequential order. Repeat steps 2-4 when installing remaining stations remembering to stay within the 2-3 foot easement from the exterior structures and 10-20 feet apart from each station. Pour 2 to 3 ounces of Non-chlorinated water into the top of the station, covering the entire horizontal surface, if possible, to expedite lowering the temperature. ![]() Step 4: Expedite lower temperature ( option ). Repack tightly in order to prevent wash out and maintain the stability of the station. The excess dirt extracted from drilling can be used to refill any air gaps around the outside circumference of the station. Ensure that the station is level and that the top of the station rests firmly to the ground. Place the open end of the station (further known as “bottom”) inside the properly drilled hole. At this point 2 to 3 ounces of Non-chlorinated water may be added to the base of the borehole to lower temperature. The stations come pre-assembled, requiring the operator only a few steps for proper installation. The HomeGuard™ Monitoring Station is a self-enclosed single process station. Step 3: Inserting the HomeGuard™ Monitoring Station. Excess grass may need to be removed from the area surrounding the hole, so that the trap may sit, flush to the dirt. Ensure that all debris such as leaves chips, branches or roots are removed from hole. If over drilling occurs, then refill with dirt to the desired level without firmly packing the dirt at the base. Proper installation requires pest professional to drill a minimum of a 5 1/2-inch deep hole to a maximum of an 6-inch deep hole. Attach Auger drill bit to cordless drill and check. We recommend starting by garage and traveling around the home ending at the other side of the garage. ![]() Remember to keep stations accessible for future visits. AND each station should sit approximately 10-20 feet apart. The stations must sit 2-3 feet away from exterior perimeter wall and/or appendages such as patios, sidewalk, pools, etc. Place stations in desired spots around the perimeter of the house. Gloves are required to keep human smell off bait matrix. HomeGuard™ Truth Termite Bait replacement cartridges or any standard E.P.A registered chemical bait matrix.Ī certified termite prevention employee with a current state identification card is mandatory. HomeGuard™ Bait Matrix Replacement CartridgesĦ. Standard graph paper with activity station log sheetsĥ. Standard HomeGuard™ Monitoring Stations.Ĥ. A high torque electric drill with charger or similar substitute drill.ģ. HomeGuard™ Monitoring System Field ManualĮvery installer requires these products for a successful installation and use of product:ġ. TRUTH TERMITE BAIT CONSUMER PRODUCT INFORMATION FACT SHEET: ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |